Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Solid |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Construction | Material | Diameter(mm) |
Inner Conductor | CCS/BC | 0.81 |
Dielectric | FOAM PE | 3.57 |
First Shield | AL Foil | 100% |
Second Shield | AL-MG/CCA Braid | 30%~60% 0.16 or 0.12mm Aluminum Wire |
Inner Jacket | PVC/PE | 6.0 |
Power Cores Conductor | CCA Stranded | 7*0.38/24*0.2 |
Power Cores Insulation | PVC/PE | 1.8 |
Outer Jacket | PVC/PE UV Resistance | 4.2 |
Electrical Characteristics | |
Impedance (Ω) | 75±3 |
Capacitance (pF/m) | 52±2 |
Velocity of Propagation(%) | 85.0 |
4.Shielding Effectiveness(dB) | 100 |
5.Operating Temp(℃) | -40~+80 |
6.Min. Bend Radius(mm) | 152 |
7.ROHS | COMPLY |
Return Loss | |
5-1000MHz(dB) | ≥22 |
1000-3000MHz(dB) | ≥20 |
Attenuation(@20℃) | ||
Frequency (MHZ) | Min Attenuation (dB/100ft) | Max Attenuation (dB/100m) |
5 | 0.86 | 2.82 |
55 | 2.05 | 6.73 |
300 | 4.45 | 14.6 |
600 | 6.2 | 20.34 |
1000 | 8.12 | 26.64 |
1450 | 9.88 | 32.41 |
1800 | 11.81 | 38.72 |
2200 | 13.05 | 42.78 |
TYPE | Conductor | Insulation | Braid Shield | Jacket | |||||
No./mm | MTRL | mm | MTRL | No./mm | No./mm | MTRL | O.D mm | MTRL | |
RG-6/U | 1/1.02 | BC | 4.57 | FPE | AF | 95% | TC | 6.9 | PVC |
RG-8/U | 7/0.9 | BC | 7.24 | FPE | 95% | - | BC | 10.3 | PVC |
RG-8/U | 7/0.724 | BC | 7.24 | PE | 95% | - | BC | 10.3 | PVC |
RG-8/X | 19/0.287 | BC | 3.94 | FPE | 95% | - | BC | 6.15 | PVC |
RG-11/U | 1/1.63 | BC | 7.24 | FPE | DF | 75% | TC | 10.3 | PVC |
RG-14/U | 1/2.591 | BC | 9.4 | PE | 97% | 97% | BCBC | 13.8 | PVC |
RG-58/U | 1/0.8 | BC | 2.9 | PE | 95% | - | TC | 5.0 | PVC |
RG-58A /U | 19/0.203 | TC | 2.9 | FPE | AF | 97% | TC | 5.03 | PVC |
RG-58A /U | 19/0.18 | TC | 2.95 | PE | 95% | - | TC | 4.95 | PVC |
RG-58C /U | 19/0.18 | TC | 2.95 | PE | 95% | - | TC | 4.95 | NC-PVC |
RG-59/U | 7/0.254 | BC | 3.71 | FPE | 95% | - | BC | 6.15 | PVC |
RG-59/U | 1/0.81 | BC | 3.71 | FPE | AF | 85% | BC | 6.15 | PVC |
RG-59/U | 1/0.643 | CCS | 3.71 | PE | 95% | - | BC | 6.15 | PVC |
RG-59A /U | 17/0.16 | BC | 3.71 | PE | 95% | - | BC | 6.15 | NC-PVC |
RG-59B/U | 1/0.584 | CCS | 3.71 | PE | 95% | - | BC | 6.15 | NC-PVC |
RG-62/U | 1/0.643 | CCS | 3.71 | SSPE | 95% | - | BC | 6.15 | PVC |
RG-62A /U | 1/0.643 | CCS | 3.71 | SSPE | 95% | - | BC | 6.15 | NC-PVC |
RG-62B/U | 7/0.203 | CCS | 3.71 | SSPE | 95% | - | BC | 6.15 | NC-PVC |