Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Construction | Material | Diameter(mm) |
Inner Conductor | CCS | 19*0.18 |
Dielectric | Solid PE | 2.95 |
Shield | TC Braid | 96*0.12 |
Jacket | PVC/PE | 5.0 |
Electrical Characteristics | |
Impedance (Ω) | 50±2 |
Capacitance (pF/m) | 100±5 |
Velocity of Propagation(%) | 66.0 |
Max Voltage | 1,500vms |
Max Frequency | 3000Mhz |
Return Loss | |
5-1000MHz(dB) | ≥22 |
1000-3000MHz(dB) | ≥20 |
Attenuation(@20℃) | ||
Frequency (MHZ) | Min Attenuation (dB/100ft) | Max Attenuation (dB/100m) |
30 | 1.9 | 6.3 |
50 | 2.46 | 8.1 |
150 | 4.3 | 14.1 |
220 | 5.2 | 17.1 |
450 | 7.5 | 24.6 |
900 | 10.7 | 35.0 |
1500 | 13.4 | 45.6 |
1800 | 15.3 | 50.1 |
2000 | 16.1 | 53 |
2500 | 18.1 | 59.5 |
5800 | 28.3 | 93.1 |